IX. TROUBLESHOOTING
Your appliance will warn you if the temperature(s) is/are at improper levels or if a problem occurs
with the appliance. In case of a problem within the appliance, the alarm led will release red light.
Alarm indicator LED
is turning on
MEANING
WHY
WHAT TO DO
"Failure" Warning
There is/are some part(s) out of
order or there is a failure in the
cooling process.
The product is plugged
for the first time or
a long-time power interruption
for 1 hour.
Check the door is open or not and check if
the product working 1 hour. If the door is
not open and the product had worked 1
hour, call service for assistance as soon as
possible.
If you are experiencing a problem with your appliance, please check the following before contacting
the after-sales service.
Your appliance is not operating
Check if:
There is power
The plug is correctly placed in the socket
The plug fuse or the mains fuse has blown
The socket is defective. To check this, plug another working appliance into the same socket.
The appliance performs poorly
Check if:
The appliance is overloaded
The appliance door is closed properly
There is any dust on the condenser
There is enough space near the rear and side walls.
Your appliance is operating noisily
Normal noises
Cracking noise occurs:
During automatic defrosting
When the appliance is cooled or warmed (due to expansion of appliance material).
Short cracking noise occurs: When the thermostat switches the compressor on/off.
Motor noise: Indicates the compressor is operating normally. The compressor may cause more noise
for a short time when it is first activated.
Bubbling noise and splash occurs: Due to the flow of the refrigerant in the tubes of the system.
Water flowing noise occurs: Due to water flowing to the evaporation container. This noise is normal
during defrosting.
Air blowing noise occurs: In some models during normal operation of the system due to the
circulation of air.
The edges of the appliance in contact with the door joint are warm
Especially during summer (warm seasons), the surfaces in contact with the door joint may become
warmer during the operation of the compressor, this is normal.
There is a build-up of humidity inside the appliance
Check if:
All food is packed properly. Containers must be dry before being placed in the appliance.
The appliance door is opened frequently. Humidity of the room enters the appliance when the
doors are opened. Humidity increases faster when the doors are opened more frequently, especially
if the humidity of the room is high.