Handleiding
Je bekijkt pagina 20 van 88

www.heinner.com
19
Error codes
The induction hob is equipped with a self diagnostic function. With this test the technician is able to check
the function of several components without disassembling or dismounting the hob from the working surface.
Problem
Possible causes
What to do!
No auto-recovery
E1
Ceramic plate temperature sensor
failure–open circuit.
Check the connection or replace the
ceramic plate temperature sensor.
E2
Ceramic plate temperature sensor
failure- -short circuit.
E7
Ceramic plate temperature sensor failure
C1
High temperature of ceramic plate
sensor.
Wait for the temperature of ceramic plate
to return to normal.
Touch “ON/OFF” button to restart unit.
E3
Temperature sensor of the IGBT failure –
open circuit.
Replace the power board.
E4
Temperature sensor of the IGBT failure –
short circuit
C2
High temperature of IGBT.
Wait for the temperature of IGBT to return
to normal.
Touch “ON/OFF” button to restart unit.
Check whether the fan runs smoothly; if
not, replace the fan.
EL
Supply voltage is below the rated voltage.
Please check whether power supply is
normal.
Power on after the power supply is normal.
EH
Supply voltage is below the rated voltage.
EU
Communication error.
Reinsert the connection between the
display board and the power board.
Replace the power board or the display
board.