Make sure that the flame does not go out by quickly turning from maximum flow to minimum flow. If it
does then remove the control knob and make further adjustments to the gas flow, testing it again once the
adjustment has been made.
4. Repeat this process for each one of the gas taps.
Do not dismantle the tap shafe: in the event of a malfunction, change the whole tap.
Before placing the burners back on the top place, make sure that the injector is not blocked.
A full operational test and a test for possible leakages must be carried out after gas conversion, (such as
soap water or gas detector).
After completing conversion, a qualified technician or installer has to mark “V” on the right gas
category to match with the setting in rating plate. Remove the previous setting “V” mark.
5. USING THE APPLIANCE
USING THE APPLIANCE
The following symbols will appear on the control panel, next to each control handle:
Black circle : gas off
Large flame : maximum setting
Small flame : minimum setting
The minimum setting is at the end of the anti-clockwise rotation of the control handle.
All operation positions must be selected between the maximum and minimum position.
The symbol on the control panel, next to the control handle will indicate which burner it operates.
Automatic ignition with flame failure safety device
The appliance is fitted with a flame failure safety device on each burner, which is designed to stop the
flow of gas to the burner head in the event of the flame going out.
To ignite a burner:
-Press in the control knob of the burner that you wish to light and turn it anti-clockwise to the maximum
position.
-If you keep the control knob depressed, the automatic ignition for the burner will operate.
-You should hold down the control knob for 15 seconds after the flame on the burner has lit. If after 15s the
burner has not lit, stop operating the device and open the compartment door and/or wait at least 1 min
before attempting a further ignition of the burner.
-After this 15-second interval, to regulate the flame you should continue turning the control knob anti-
clockwise until the flame is at a suitable level. The operating position MUST be at a position between the
maximum and minimum position.
-To switch the burner off, turn the control knob fully clockwise to the gas off position.
-In case of power failure, the burners can be lit by carefully using a match.