4. FUNCTIONS
Auto-Restart
If the unit loses power, it will automatically restart with the prior settings once power has been restored.
Wi-Fi Control
Wi-Fi control allows you to control your air conditioner using your mobile phone and a Wi-Fi connection.
For the USB device access, replacement, maintenance operations must be carried out by professional staff.
Louver Angle Memory
When turning on your unit, the louver will automatically resume its former angle.
Refrigerant Leakage Detection
The indoor unit will automatically display “EC” or “EL0C” when it detects refrigerant leakage.
Low ambient cooling
With low ambient cooling function, the outdoor fan speed can be changed according to the condenser
temperature and AC can run smoothly under the temperature as low as -15°C (5°F).
Air Fresh function
The ion generator is energized and will help to purify the air in the room.
Active Clean function
• The Active Clean Technology washes away dust when it adheres to the heat exchanger by automatically
freezing and then rapidly thawing the frost. A “pi-pi” sound will be heard. The Active clean operation is used
to produce more condensed water to improve the cleaning effect, and the cold air will blow out. After
cleaning, the internal wind wheel then keeps operating with hot air to blow-dry the evaporator, thus keeping
the inside clean.
• When this function is turned on, the indoor unit display window appears “CL”, after 20 to 130 minutes, the
unit will turn off automatically and cancel Active Clean function.
• For some units, the system will start high- temperature cleaning process, and the temperature of air outlet
is very high. Please keep away from it. And this would lead to the rising of the room temperature.
Sleep operation
• The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature
settings to stay comfortable). This function can only be activated via remote control. And the Sleep function
is not available in FAN or DRY mode.
• Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will increase the
temperature by 1°C (2°F) after 1 hour and will increase an additional 1°C (2°F) after another hour. When in
HEAT mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour and will decrease an
additional 1°C (2°F) after another hour.
• The sleep feature will stop after 8 hours and the system will keep running with final situation.