10. When moving or relocating the air conditioner, consult experienced service technicians for disconnection
and reinstallation of the unit.
11. How to install the appliance to its support, please read the information for details in "indoor unit
installation" and "outdoor unit installation" sections.
Fluorinated Gasses (Not applicable to the unit using R290 Refrigerant)
1. This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the type of
gas and the amount, please refer to the relevant label on the unit itself or the “Owner's Manual - Product
Fiche ” in the packaging of the outdoor unit. (European Union products only).
2. Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
3. Product uninstallation and recycling must be performed by a certified technician.
4. For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2 equivalent or
more, but of less than 50 tonnes of CO2 equivalent, If the system has a leak- detection system installed, it
must be checked for leaks at least every 24 months.
5. When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
Warning for using R32/R290 refrigerant
• When flammable refrigerant are employed, appliance shall be stored in a well -ventilated area where the
room size corresponds to the room area as specified for operation.
For R32 refrigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger than 4m 2. Appliance shall
not be installed in an unventilated space, if that space is smaller than 4m2.
For R290 refrigerant models, the minimum room size needed:
<=9000Btu/h units: 13m2
>9000Btu/h and <=12000Btu/h units: 17m2
>12000Btu/h and <=18000Btu/h units: 26m2
>18000Btu/h and <=24000Btu/h units: 35m2
• Reusable mechanical connectors and flared joints are not allowed indoors. (EN Standard Requirements).
Mechanical connectors used indoors shall have a rate of not more than 3g/year at 25% of the maximum
allowable pressure. When mechanical connectors are reused indoors, sealing parts shall be renewed. When
flared joints are reused indoors, the flare part shall be re-fabricated. (UL Standard Requirements)
When mechanical connectors are reused indoors, sealing parts shall be renewed. When flared joints are
reused indoors, the flare part shall be re-fabricated.
(IEC Standard Requirements)
• Mechanical connectors used indoors shall comply with ISO 14903.
Disposal guidelines
This appliance contains refrigerant and other potentially hazardous materials. When disposing of this
appliance, the law requires special collection and treatment. Do not dispose of this product as household
waste or unsorted municipal waste.
When disposing of this appliance, you have the following options:
• Dispose of the appliance at designated municipal electronic waste collection facility.
• When buying a new appliance, the retailer will take back the old appliance free of charge.
• The manufacturer will take back the old appliance free of charge.
• Sell the appliance to certified scrap metal dealers.
Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for