The Unit’s 3-minute protection has
been activated
Wait three minutes after restarting the unit
Timer is activated
Turn timer off
The unit starts and
stops frequently
There’s too much or too little refrigerant
in the system
Check for leaks and recharge the system with
refrigerant.
Incompressible gas or moisture has
entered the system.
Evacuate and recharge the system with
refrigerant
The compressor is broken
Replace the compressor
The voltage is too high or too low
Install a manostat to regulate the voltage
Poor heating
performance
The outdoor temperature is extremely
low
Use auxiliary heating device
Cold air is entering through doors and
windows
Make sure that all doors and windows are
closed during use
Low refrigerant due to leak or long-term
use
Check for leaks, re-seal if necessary and top
off refrigerant
Indicator lamps
continue flashing
The unit may stop operation or continue to run safely. If the indicator lamps continue to
flash or error codes appear, wait for about 10 minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact your nearest customer service
center.
Error code appears in
the window display of
indoor unit:
• E(X), P(X), F(X)
EH(XX), EL(XX), EC(XX)
PH(XX), PL(XX), PC(XX)
Note: If your problem persists after performing the checks and diagnostics above, turn off your unit
immediately and contact an authorized service center.