Heinner CH-MD190BK handleiding

43 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 43
www.heinner.com
6
Wall mounting installation
To mount on the wall, drill two10mm diameter holes 538mm with the vent hole on the top of the cooker
hood in the middle as below picture. Make sure the hood is aligned directly over the hob.
Insert two plastics wall plugs(supplied) into the holes.
Insert two screws into the upper two plastic wall plugs and tighten them leaving 3mm protruding from
the wall.
Mount the cooker hood onto the two screws and mark the bottom two screw positions.
Remove the hood and drill the bottom two screw holes and insert the plastic wall plugs.
Mount the hood on the top screws, Insert the bottom screws and fully tighten all the screws.
6. USE OF THE APPLIANCE
Lighting
Light replacement
Switch off the extractor hood and isolate the extractor hood by pulling out the mains plug or switching
off the fuse.
Remove the grease filter.
Remove the light by levering its fitting from the hood body (this may require pressure or force to be
applied).
Disconnect the connector of the light.
Replace the light with a new one of the same type, making sure that you connect the light with the light
cable correctly.
Reconnect the power by inserting the mains plug or by switching on the fuse.
Max power
Voltage
Picture
ILCOS D code
Self-ballasted LED
modules
1.5 W
220V-240V~
Square/Diameter: 33.2mm x
120mm
DBS-1.5-H-33.2/120
Clean ventilation frequently. Grease should not be allowed to accumulate on fan or filter.

Bekijk gratis de handleiding van Heinner CH-MD190BK, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHeinner
ModelCH-MD190BK
CategorieAfzuigkap
TaalNederlands
Grootte9471 MB