Hedbox NINA Mg handleiding

17 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 17
# 8
Power
Status
K.
J.
I.
8 Amp 9 Amp 10 Amp 11 Amp 12 Amp
OP OP
Battery OFF
OP
±5%
BMS OLED Display warning code
OP Code / Battery system OVER POWER
When the battery is overpowered during the discharging/draining.
The automatic BMS protection system activates the OP Code on the OLED.
OT Code / Battery system OVER TEMPERATURE
When the battery hase reach high temperature during operation.
The automatic BMS protection system activates the OT Code on the OLED.
The OLED display shows a flashing OP code (Photo I.)
• The IDR LED Ring will flash and illuminate a RED color.
• The battery will still supply power; however, the BMS system
advises against extensive use at this point, as it could potentially
jeopardize the safety integrity of the battery.
The OLED display shows a flashing OT code (Photo J.)
• The IDR LED Ring will flash and illuminate a RED color.
Battery Charging Proccess
• Battery's BMS protection system will automatically deactivate the
battery to safeguard its integrity if the temperature exceeds 45°C
Battery Discharging / Draining Process
• Battery's BMS protection system will automatically deactivate the
battery to safeguard its integrity if the temperature exceeds 60°C
Note: When are the batteries returned to their standard operating conditions? The battery's automatic BMS system will reset and revert
to factory default settings, ensuring the smooth operation and energy supply of the battery.
• If the battery is overloaded more than the maximum power out,
the BMS will shoot down the battery to protect its integrity.
UT Code / Battery system UNDER TEMPERATURE
When the battery hase reach low temperature during operation.
The automatic BMS protection system activates the UT Code on the OLED.
The OLED display shows a flashing UT code (Photo K.)
• The IDR LED Ring will flash and illuminate a RED color.
Battery Charging Proccess
• Battery's BMS protection system will automatically deactivate the
battery to safeguard its integrity if the temperature falls below 0°C.
Battery Discharging / Draining Process
• Battery's BMS protection system will automatically deactivate the
battery to safeguard its integrity if the temperature falls below -10°C.
EN
English

Bekijk gratis de handleiding van Hedbox NINA Mg, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHedbox
ModelNINA Mg
CategorieNiet gecategoriseerd
TaalNederlands
Grootte4888 MB