CHIMNEY MAINTENANCE
The chimney connector and Saf-T Liner should be inspected frequently
during the heating season and cleaned annually (more often if necessary)
by a professional, certified chimney sweep. Formation of creosote and
soot and the need for removal occurs when wood is burned slowly,
producing tar and other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors condense in the relatively
cool flue of a slow burning fire. As a result, creosote residue accumulates
on the flue lining. If ignited, this can make an extremely hot chimney fire.
The chimney should be inspected at least every 6 to 8 weeks during the
woodburning season to determine if a creosote or soot buildup has
occured. To inspect and/or clean the chimney, loosen the four Tek screws
with a nutdriver and remove the rain cap. If creosote or soot have
accumulated, have the chimney professionally cleaned to reduce the risk
of a chimney fire.
A round-wire steel or Poly chimney cleaning brush is recommended to
clean the Saf-T Liner. Heat-Fab does not recommend the use of chemical
chimney cleaners which may be harmful to the Saf-T Liner. After thor-
oughly cleaning the chimney re-install the rain cap by using the four Tek
screws.
WARNING! Do not use any loose fill, cementious, or
blanket insulation thicker than 1/4 inch equivalent
refractory ceramic fiber. These products void the
Saf-T Liner and may create unsafe conditions
resulting in damage to the masonry chimney and/or
the liner system.
Rain Cap
Storm Collar
Cover Plate
Saf-T Liner
Saf-T Wrap
Appliance Tee
Clean Out Tee
Tee Cover
Fig. 7
Fill
Saf-T Liner Stainless Steel Chimney Liner
Limited Warranty
Heat-Fab, Inc. warrants to the original consumer purchaser that the Type 304 Saf-T Liner will be free from defects in material
or manufacturer’s workmanship when properly installed with Saf-T Wrap insulation pursuant to these manufacturer’s
installation instructions and according to the local building codes, when used under normal conditions as connector pipe or
chimney relining material for Wood Burning residential appliances Tested and Listed by a recognized laboratory, or site build
masonry fireplaces and when inspected and cleaned by a certified professional at the consumer’s expense at intervals of no
more than twelve (12) months, commencing from the date of purchase, as verified below.Type 316 Saf-T Liner will be free from
these same defects when connected to coal burning appliances for a period of 10 years.
In order to obtain warranty service, the consumer must give prompt written notice of any defect to Heat-Fab, Inc. at it's current
address or via e-mail to mail@heat-fab.com. The sole responsibility of Heat-Fab, Inc. shall be to replace those lengths of
liner found to be defective upon return F.O.B. to the Heat-Fab factory. Heat-Fab, Inc. shall not be responsible for the cost
of removing or installing the lengths which are subject hereto, nor shall it be liable for any special, incidental or consequential
damages or expenses incurred by the consumer.
This warranty gives the consumer specific legal rights, in addition to any other rights which may pertain, which vary from state
to state.