FOLLOW THESE CHIMNEY MAINTENANCE INSTRUCTIONS:
The chimney connector and Saf-T Liner should be inspected frequently during the heating season and cleaned
annually (more often if necessary) by a professional, certified chimney sweep.
The chimney should be inspected at least every 6 to 8 weeks during the heating season and once prior to the
season to determine if (1) a creosote or soot buildup has occured or (2) if some other mechanism has caused
a failure of the liner system. To inspect and/or clean the chimney, loosen the four Tek screws with a nutdriver
and remove the rain cap. If creosote or soot has accumulated, have the chimney professionally cleaned to
reduce the risk of a chimney fire.
Properly installed and well maintained stovepipes and chimneys can usually withstand an occasional moderate
chimney fire, but the intentional setting of a chimney fire to "burnout" the creosote should be avoided. This is
a dangerous method to clean a chimney and can cause severe damage to chimneys, liners and possible
damage to the structure of the house.
After any chimney fire always have the chimney system inspected by a knowlegeable and certified professional
before any further use. The excessive heat during a chimney fire can crack chimney walls, and cause cracking,
buckling, distortion and/or burnout in chimney liners. A chimney liner damaged in such a way as to permit
leakage of flue gases should be repaired or replaced, since there is a greater likelihood that a subsequent
chimney fire could spread beyond the confines of the damaged flue to the house itself. If no such damage is
visible the chimney system, installed per these instructions, is suited for further use subject to the inspection
schedule outlined above.