TROUBLESHOOTING PROCEDURE
PROBLEM CONDITION
REPAIR CHECKLIST
1.
Cold flow only.
a.
Confirm the hot water inlet pressure; it must be within +/-
10% of the cold inlet pressure.
b.
c.
Confirm the hot water check-stop and/or upstream valve
is fully open.
Confirm the hot inlet check-stop screen is free of debris.
Clean if necessary.
2.
Flow rate is too low.
a.
Confirm all upstream inlet valves are fully open.
b.
Confirm the downstream valve is fully open.
c.
d.
Confirm the hot and cold inlet pressures; both supplies
must be 30 PSI, minimum.
Confirm both the check-stops are free of debris. Clean if
necessary.
3.
No flow.
a.
Confirm all upstream inlet valves are fully open.
b.
Confirm the downstream valve is fully open.
c.
d.
Confirm the hot and cold inlet pressures; both supplies
must be 30 PSI, minimum.
Confirm both the check-stops are free of debris. Clean if
necessary.
4.
Significantly lower outlet
temperature.
a.
Confirm the hot water inlet pressure; it must be within +/-
10% of the cold inlet pressure.
b.
Confirm the cold water bypass valve is free of debris.
Clean if necessary.