d. Insert the flexible duct into the intake bracket. Bend the tabs
on the duct collar to the outside to secure the flexible duct.
Support du
conduit d’admission
Languettes du
collet de conduit
Installing the Flexible Duct to the Intake Bracket
6. Clean the well enclosure thoroughly in preparation for
initial operation. Refer to the MAINTENANCE section for
proper cleaning procedures.
NOTE: If a catch pan is used underneath the drain fitting, make
sure the pan is emptied regularly to prevent over-flowing.
7. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See
the SPECIFICATIONS section for details.
Installing the Remote Control Panel
Use the following procedure to install the control panel remotely.
WARNING
Control panel must be mounted in a vertical surface.
Mounting control panel in a horizontal surface may result
in the collection of liquids and lead to electric shock.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the “Control Panel Cutout and Screw Hole
Dimensions” chart for the cutout dimensions.
2. Remove the control box from the unit by removing the
bolts on the side of the condensing unit.
3. Remove the four trim cover screws from the control box
and remove the trim cover.
4. Remove the bracket from the control box by unscrewing
the four bracket screws.
5. Position the control box into the cutout opening from the
backside.
6. Fasten the control box to the vertical surface using four
screws (not supplied).
7. Apply a 1/4″ (6 mm) bead of NSF-approved silicone sealant
where the trim cover will contact the cabinet surface. Refer
to the “Control Panel Cutout and Screw Hole Dimensions”
illustration for more information.
8. Reinstall the trim cover on the control panel and secure
in position using the four trim cover screws. Make sure to
embed the trim cover edge into the silicone.
7/16″
(11 mm)
3/8″
(9 mm)
Silicone Sealant
5-5/8″
(143 mm)
7-7/16″
(189 mm)
7-3/4″
(196 mm)
3-1/2″
(89 mm)
1-1/16″
(27 mm)
Control Panel Cutout and Screw Hole Dimensions
NOTE: Make sure the width of the control panel cutout does
not exceed the above dimension.