10 CWBPSM-0225
English
INSTALLATION
Installing the Unit
NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Lift the unit out of the shipping frame and carefully lower it
into the countertop cutout.This step requires two or more
people, depending on the unit.
2. Apply NSF-approved silicone sealant around the edge of
the unit to seal it to the countertop.
NOTE: If excessive condensation appears underneath the
countertop during operation, apply polyurethane-based
foam sealant in the gap between the underside of the
countertop and the unit.
Exhaust
Air Flow
Exhaust
Air Flow
Intake
Air Flow
Ventilation
Openings
(on opposite sides
of condenser coils)
Condenser Coils
(inside duct collar)
Countertop Cutout
Fully sealed
partition between
additional units
inside the same
cabinet.
Installing a CWBPS-2 Model
WARNING
FIRE HAZARD:
Install unit in a cabinet enclosed on all four sides.
Use caution and avoid hitting condensing unit hoses/
lines when installing unit. Damage caused during
installation is not covered under warranty.
Condensing unit must be isolated from other electrical
devices in the cabinet with fully sealed partitions.
DO NOT use installation cabinet for storage of any
items. Cabinet must be used only to keep condensing
unit isolated from all other objects.
To prevent damage to components, condensing unit
should not be readily accessible to users/operators.
3. Install the control panel in the desired location.
The control panel can be installed on one of three sides
of the condensing unit support frame. Do not install the
control panel in front of the condenser coils.
The control panel can be installed remotely within 48″
(1219 mm) of the condensing unit. Refer to the “Installing
the Remote Control Panel” procedure in this section.
4. Connect the 1″ drain fitting to a trap and drain line. If a
trap and drain line are not available, a catch pan (not
supplied) must be used under the drain fitting to contain
water draining from the well enclosure.
NOTE: Consult a qualified plumber for proper trap and drain
installation that conforms to local plumbing codes.
5. Install the intake air ducting.
a. Install the Intake Bracket to the inside of the cabinet
over the 12″x12″ cutout.
Intake
Bracket
Screw
Installing the Intake Bracket
b. Install the flexible duct to the duct collar on the
condensing unit using the duct clamp.
c. Install the duct collar on the other end of the flexible duct
using the duct clamp.
Duct Collar
Duct Clamp
Flexible Duct
Duct Collar
Installing the Flexible Duct