CWBPM-0525
English
INSTALLATION
General
Refrigerated Drop-In Wells are shipped from the factory completely
assembled and ready for use. Use the following information and
procedures to prepare the unit and installation site.
DANGER
EXPLOSION HAZARD:
• Do NOT puncture refrigerant tubing. Use extreme
caution and follow all local/regional codes for
transportation or relocation of hydrocarbon equipment.
• Do NOT move or rotate condensing unit. Damage to
refrigerant tubing will occur.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this equipment.
• Smoking is strictly prohibited near equipment with
R-290 (hydrocarbon) refrigerant.
This unit uses flammable refrigerant. Follow handling
instructions carefully in compliance with US and/or
Canadian government regulations.
Do NOT use electrical appliances inside of the food storage
compartments or inside the cabinet under the unit.
Do NOT use mechanical devices or any other means to
accelerate the defrosting process. Follow the “Setting the
Auto-Defrost Cycle” procedure in the OPERATION section
in this manual to defrost ice buildup.
Keep all ventilation openings clear of obstructions at all
times.
WARNING
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install proper voltage and
size electrical receptacle.
• Unit is not weatherproof. Locate unit indoors.
FIRE HAZARD:
• Install unit with a minimum of 7″ (178mm)of space
between all sides of condensing unit and any
combustible surfaces.
• For closed cabinet installations, provide louvered or
grill-styleopeningswithasizeof12″x12″/144square
inches (31 x 31 cm/961 square cm) in the cabinetry
in front of and behind the condensing unit for proper
ventilation. Failure to provide adequate air flow through
the condensing unit may cause fire and/or unit failure
and will void the unit warranty.
• Allelectricalreceptaclesmustbeatleast12″(305mm)
above the cabinet floor.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
CAUTION
Locate unit at the proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
NOTICE
Transport and install unit in upright position only. Failure
to do so may result in damage to refrigeration system.
For proper operation in closed cabinet installations, this
unit must be installed with intake ducting. Failure to install
properly will void warranty.
When shipped during cold weather months, store unit in
proper ambient temperature environment for 10 hours to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warm up time.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
All Refrigerated Drop-In Wells are shipped in a shipping frame
for protection and stability. Keep the unit in the shipping frame
until the unit and the installation site are completely prepared
for the unit to be installed.
1. Remove all external packaging from the unit.
2. Remove tape, protective packaging, and literature from all
surfaces of the unit.
NOTE: To prevent delay in obtaining warranty coverage, complete
online warranty registration. See the IMPORTANT
OWNER INFORMATION section for details.
Preparing the Installation Site
Refrigerated Drop-In Wells can be installed into either open
cabinet or closed cabinet configurations.
For all installations, the condensing unit must be isolated from
other electrical devices in the same cabinet using fully sealed
partitions. The cabinet must allow access for ventilation, control
access, and maintenance/cleaning access.
NOTICE
This unit is designed for use in environments where
ambient cabinet temperature is between 65°F (18°C) and
86°F (30°C).
All Installations
1. Cut the appropriate opening in the countertop for the unit
being installed. Refer to “Countertop Cutout Dimensions”
in this section.
2. Make preparations for control panel installation. Refer to
the “Installing the Unit” and “Installing the Remote Control
Panel” procedures for additional information and cutout
dimensions.
• If installing the control panel remotely, cut and drill the
appropriate holes in the vertical surface where the
control panel will be installed.
• If installing the control panel on the condensing unit
frame, cut an opening in the cabinet for access to the
control panel, if necessary.
3. If necessary, cut an opening in the cabinet for access to the
condensing unit coils for cleaning. Louvered or grill-style
panels should be installed in the openings to protect the
condensing unit.
4. Make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents. Make sure a minimum
7″ (178 mm) clearance will be available between the
condensing unit and any interior surface.