Hansgrohe Ecostat S handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 72
7
English
Assembly (see page 60)
Fault Cause Remedy
Insufficient water - Supply pressure inadequate - Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty - Clean filter in front of the mixer and
on the MTC-thermo cartridge
- Shower filter seal dirty
- filter insert shower dirty
- Clean filter seal between shower
and hose
- Clean filter insert between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or leak-
ing
- Clean backflow preventers, ex-
change if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted - Adjust thermostat
- Hot water temperature too low - Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible - thermo cartridge calcified - Exchange thermo cartridge
- For new installations: basic body in-
correctly connected (should be:
cold right, hot left) or installed with
180º rotation
- Install function block turned through
180º
Safety stop button not operating - Spring defective
- Button calcified
- Clean spring and/or button, ex-
change if necessary
Diverter leaking - Dirt or sedimentation on valve seat. - Clean valve seat or exchange di-
verter
Valve stiff - Diverter defective - Exchange diverter

Bekijk gratis de handleiding van Hansgrohe Ecostat S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHansgrohe
ModelEcostat S
CategorieNiet gecategoriseerd
TaalNederlands
Grootte7941 MB