Hansgrohe AXOR Uno 16182180 handleiding
Handleiding
Je bekijkt pagina 4 van 40

0, 1,
2
04
ASSEMBLY (see page 34)
PROTECTED AREA (see page 33)
DIMENSIONS (see page 32)
Water connection DN20 Cold water
Water connection DN20 Warm water
6 V
230 V
Empty pipe
transformer
Do not use silicone containing acetic acid!
SYMBOL DESCRIPTION
SAFETY NOTES
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
ELECTRICAL CONNECTION
The installation and testing work must be performed by a skilled electrician in
observance of VDE 0100 part 701 and IEC 60364-7-701.
The current version of the applicable regulations from VDE, local authorities and
utility companies must be observed for electric installation work.
The entire power is supplied via a 240V⁄N⁄PE⁄50Hz AC connection.
The system must be protected via a leakage current protective device (RCD⁄ FI)
with a measurement difference current of ≤ 30 mA.
The proper function of this fusing⁄protection must be checked at regular intervals.
The ambient temperature must not be higher than 50ºC.
It must be ensured that the product can be disconnected from the mains, e.g. via a
an all-pin switch as per EN 60335-1, sect. 24.3
INSTALLATION INSTRUCTIONS
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards. (Installation nach EN 1717)
⁄ Any work may only be carried out in a de-energized state.
⁄ The basic body 16182180 can only be installed vertically!
⁄ To turn in the supply pipes or to adjust the installation ring, fix the iBox with a pipe
in the vice. (see page 36)
⁄ For the transformer supplied with the ready-to-use set, a flush-mounted outlet socket
with a 230 V supply line must be provided.
⁄ The transformer must not be installed in protection zones 0, 1 or 2. (see page 33)
⁄ The flush-mounted outlet socket is connected with the basic set via an empty
conduit EN 20.
⁄ The clearance between flush-mounted outlet socket and basic set may amount to
max. 7 m
⁄ This empty pipe must be affixed at least every 500 mm and the bending radius must
be greater than 100 mm.
⁄ Up to four fittings can be connected to a transformer on a ready-to-use set
⁄ All components must remain accessible.
⁄ The gasket is not suitable for hot glue. If the iBox universal should be hot glued,
please take care that the mixer is not damaged.
⁄ The iBox can depending on the building application be mounted in different ways,
Installation examples please see page 34 and 35.
A Direct wall installation.
B Direct wall installation with 10 mm adjustable mounting studs.
C Installation on carrier system.
D Installation on prefabricated house installation panels or finished cells.
E Brick wall installation.
EN
FLUSH PIPING SYSTEM
Flush the complete installation (both hot and cold water supply) acc. to DIN 1988 ⁄
EN 1717. The arrows on the flush body are indicating which inlet is connected with
which outlet line, e.g. cold water suply with bottom outlet and hot water supply with
top outlet. As only one outlet is required, the flush body must be turned by 90º after
the first flushing.
TECHNICAL DATA
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 65°C
Recommended hot water temp.: 65°C
Thermal disinfection: max. 70°C ⁄ 4 min
The product is exclusively designed for drinking water!
OPERATION (see page 39)
SPARE PARTS (see page 31)
SPECIAL ACCESSORIES (order as an extra)
extension 25 mm #13595000 (see page 31)
TEST CERTIFICATE (see page 39)