AssemblyPage EN-12
Assembly
Space requirements
(a)
(b)
(c)
(d)
(e)
Important units:
Dimensions
in cm
(a) Minimum distance be-
tween cooker and lower edge
of exhaust hood (1)
6575
(b) Height of exhaust hood (1) 36
(c) Height of the entire flue
screen, (2) and (3)
44(50)–78
(d) Height of the entire appli-
ance, (1), (2) and (3)
80(86)116
(e) Space required above the
stovetop
145(151)–189
The images and tables show the minimum
distances that must be complied with and how
much leeway you have while installing.
The figures in brackets refer to circulation air
operation; the ventilation slits must be kept
clear.
Attachment dimensions
(g)
(f)
(i)
(j)
(h)
Calculating drill holes:
Dimensions
in cm
(f) Height of the safety screws
(12) for exhaust hood (1)
14.5
(g) Height of the fixing
screws (11) for exhaust
hood (1)
34.5
(h) Distance between the
safety screws (12) for exhaust
hood (1)
30
(i) Distance between the fix-
ing screws (11) for exhaust
hood (1)
35
(j) Distance between the fix-
ing screws (10) for the wall
bracket (6) for the upper flue
screen (2)
10.5