Safety
Page EN-7
Risks during exhaust air operation
WARNING
Risk of suffocation/explosion!
The air in the room where the exhaust
hood is operating is extracted by fan
and released outside. If, in this room, a
replace requiring indoor air – such as a
gas fi re or other fuel-based heating sys-
tem – is also in use, the oxygen that is
necessary for combustion may also be
extracted. This can result in the fl ame
being extinguished and gas being re-
leased or the room becoming saturated
with exhaust fumes.
It is possible to run the appliance wi-
thout any risk by, for example, provi-
ding non-sealable openings in doors,
windows or ventilation conduits th-
rough which the combustion air can
escape, and by achieving a negative
pressure level in the installation spa-
ce of maximum 0.04 mbar. This pre-
vents the exhaust fumes from being
sucked back into the room.
In order to determine the necessary
measures, the entire ventilation sys-
tem throughout the home must be
reviewed. Consult the gas safety
consultant who is responsible for the
home.
Never attach the exhaust hood to a
ventilation shaft, chimney or smo-
kestack! The air being extracted must
not travel through a channel in which
warm air circulates. The extracted air
may only be released to the outside
through a separate air channel inten-
ded exclusively for the exhaust hood.
NOTICE
Risk of damage to property!
For exhaust air operation, a wall or
ceiling break of at least 15.5 cm in
diameter is required.
We recommend having a specialist
(electrician) carry out this break (core
drilling).
If the exhaust air hose passes th-
rough an exterior wall, the air out-
let on the outside must have a cover
with self-opening slits (not included
in the package contents). Hire a spe-
cialist to carry out the wall break.
Consider the following: The shorter
and straighter the exhaust hose, the
more powerful the hood function will
be.
In Germany, statutory requirements
for extracting exhaust air vary from
state to state. Ask your district chim-
ney sweep for advice.