Handleiding
Je bekijkt pagina 14 van 48

14
31-5000795 Rev. 0
Installation Instructions
Final Check
Start Up Checklist
Ƒ Refrigerant charge is verified and system has been
leak tested
Ƒ Line sets have been insulated
Electrical connections are secure
Ƒ Has the electrical ground been checked and verified
Ƒ Electrical wiring terminals match at indoor and
outdoor unit
Ƒ Wire between outdoor and indoor must be 14/4
stranded
Ƒ The outdoor to indoor wires free of splices
Ƒ Condensate drain has correct pitch and has been
leak tested
Ƒ Indoor and outdoor units match
Ƒ Indoor and outdoor units are firmly mounted
Ƒ Power source voltage is within tolerances
Ƒ The indoor and outdoor sections are quiet and free
of vibration
Ƒ All functions of the controller have been verified
Ƒ Operation in cooling or heating modes is normal
Ƒ Operation of the system has been explained to the
owner
Explaining Operation to the End User
• Using the User Manual, explain to the user how to use the air conditioner/heat pump, (the remote controller,
adding/removing the air filters, placing or removing the remote controller from the remote control holder, cleaning
methods, precautions for operation, etc.)
• Review precautions for operation.
• Recommend that the user read the Operating Instructions carefully.
Bekijk gratis de handleiding van Haier USYM12UCDSA, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Haier |
Model | USYM12UCDSA |
Categorie | Airco |
Taal | Nederlands |
Grootte | 9432 MB |