12 31-5000516 Rev. 4
Installation Instructions
Step 3 - Electrical Connections
Electrical connections indoor and outdoor units
14/4 non-shielded stranded copper cable Only.
Maintain 10 feet of separation between TV and any Radio wiring.
NOTE: Tighten connector terminals to manufacturers torque rating
NOTE: If cable connecting Indoor & Outdoor unit > 180ft (55m),
the Indoor unit ground wire should be separated from the cable.
The connecting wiring between the outdoor and indoor units
should be 14-4( 14 gauge 4 conductor) SOOW cable. It is
recommended that the wire connections be made with spade
terminals. If spade terminals are not used then the wires should
not be twisted prior to connecting to the screw terminals. All
strands of the wires need to be tightened to the terminal with no
fraying. The cable should be secured with the strain relief clamp.
Step 4 - Leak Testing and Evacuation
Refer to the outdoor section Installation Manual for the recommended procedure.
Wifi Pairing
'RZQORDGWKH6PDUW+4DSSIURP*RRJOH3OD\$QGURLGRUWKH$SSOHDSSVWRUH,26
After downloading the App:
2. Open the app.
3. Select “Sign In”.
4. Sign into your account or register as a new user.
5. Select the “+” icon to add a new device and follow the directions in the app.
Step 2 - Installation of the Cassette Unit (cont)
I. ([WHUQDO,QVWDOODWLRQ+HLJKW6HWWLQJ8VLQJ4$&7$
ACT17CWA (Wired Controller)
After backlight is lit at the wired controller off, press and
hold FAN and TEMP + button for 10 seconds.
The static pressure selection will appear in the upper
right hand corner.
The Installation Height Grade can be adjusted by
pressing TEMP + or TEMP - buttons.
• Press FAN button to confirm the change.
Installation Height Grade Installation Height
1 (Default) 2.7m (8.9ft)
2 2.7 - 3.7m (8.9 - 12.1ft)
3 3.7 - 4.2m (12.1 - 13.8ft)
L1 L2
123
123
POWER SUPPLY
208/230V 60Hz
Outdoor unit
terminal blocks
Indoor unit
terminal block
&$66(7(
C1C2
central controller
A
B
B A