ENGLISH
Back test point
PCB Overview
SV
In the case of relay suction, if the output voltage of the test port is 0V (AC), it means that SV is abnormal. If it is
220V (AC), it means normal.
Electronic expansion valve
Measure the voltage between the electronic expansion valve output pin and 12V. If the voltage is 0V (DC), it means
that the electronic expansion valve is abnormal.
If the voltage is 12V (actually lower than 12V), it means normal.
(The electronic expansion valve actually has four outputs at each port, and all outputs need to be tested).