PCB Overview
Fan motor
The fan is three-phase U, V, and W, and the current between each phase is about 1A.
Multimeter DC current range tests the current between any two phases.
The fan motor is tested at about 16V DC.
Compressor
The compressor is three-phase U V W, and the current between each phase is about 1A in the no-load state of the
compressor. Multimeter DC current range Tests the current between any two phases. (The copper foil tinning on the
front of the compressor port can be tested)
terminal of fan motor Back test point
the port of compressor
terminal of four way valve Back test point
Four way valve
In the case of relay suction, if the output voltage of the test port is 0V (AC), it means that the four way valve is abnormal.
If it is 220V (AC) -15%~+10%, it means normal.