TROUBLESHOOTING & REFERENCES
Ï¡&
ENGLISH
ÎõõòõÌòçèö ¤Òñçòòõ¦Øø÷çòòõ¥
Ï&¦ÕÎÍ!!"Ïïäöë
Ambient Temperature Sensor Failure
Ï'¦ÕÎÍ!!!Ïïäöë
Suction Temperature Sensor Failure
Ï"!¦ÕÎÍ!! Ïïäöë
Defrost Temperature Sensor Failure
Ï"%¦ÕÎÍ!!#Ïïäöë
Discharge Temperature Sensor Failure
Î!¦ÕÎÍ!×òÏïäöë
Room Temperature Sensor Failure
Î"¦ÕÎÍ!×òÏïäöë
Indoor Coil Temperature Sensor Failure
Complete the “Check This First” Flow Chart before continuing.
Öòçèïö
AW24TL2HFA
AW30TL2HFA
AW36TL2HFA
Yes
Yes
Yes
Yes
No
No
No
No
Re-seat connector
Replace sensor. Go
to next step to test
the board as well
before replacing
sensor.
Replace main
board. Replace
sensor as well if
resistance was
incorrect in the
previous step.
Re-seat and
re-check sensor
resistance with a
çìģèõèñ÷ðè÷èõ
Replace sensor
Start
Is connector plugged in and
seated securely?
Disconnect power and un-plug senor
connector from the board.
Check resistance across the set of
wires for the faulting sensor. Does
the resistance correspond to the
temperature located in the respective
chart ? (See Reverse side.)
Reconnect sensor to the board and re-apply power.
Check voltage between the two corresponding
solder joints or through the top of the Molex
æòññèæ÷òõçèóèñçìñêòñöèñöòõæòñĤêøõä÷ìòñ
Is the voltage ~5VDC?
Is the temperature at the
sensor out of operating
range (+/- 3%)?
ÝÛØÞËÕÎÜÑØØÝÒ×ÐÏÕØàÌÑÊÛÝÜ