TROUBLESHOOTING & REFERENCES
Ï¡#
ENGLISH
ÎõõòõÌòçè ¤Òñçòòõ¦Øø÷çòòõ¥
Ï!¦ÕÎÍ!"Ïïäöë
IPM Power Module Fail
(IPM power module protection)
Complete the “Check This First” Flow Chart before
continuing.
Öòçèïö
AW24TL2HFA
AW30TL2HFA
AW36TL2HFA
Yes
No
No
Yes
Yes No
Start
Cycle power to the outdoor
øñì÷ÍòèöÕÎÍ!ĥäöë"÷ìðèö
before the compressor starts?
Compressor runs for 10 min.
and stops with LED in center of
ÙÌËĥäöëìñê"÷ìðèö
DC voltage from P-U, P-V, P-W is 150-160VDC,
DC voltage from N-U, N-V, N-W 150-160VDC?
Replace IPM
Replace IPM
Normal
operation
Check coil cleanliness,
EEV operation, compressor
windings, and refrigerant charge
ÝÛØÞËÕÎÜÑØØÝÒ×ÐÏÕØàÌÑÊÛÝÜ
Yes
Yes
No
Yes
No
No
Yes
Yes
No
No
Yes
Continue to monitor; the
system is starting under
an abnormal load
Replace IPM
Replace IPM
Check refrigerant charge
Start
The set temperature is 5°F max.
from the room temperature?
Does the error code display
before the compressor starts?
àì÷ëóòúèõòģéòõ
5 min and back on,
compressor exceeds
over-current point in
Service Manual?
There is pulsing 50-200
VAC at compressor
terminals U, V, and W , read
from the terminal solder
points on the IPM?
There is 264-373 VDC at
P and N on the IPM?
Change set temperature
ÎõõòõÌòçè ¤Òñçòòõ¦Øø÷çòòõ¥
Ï"¦ÕÎÍ!"$Ïïäöë
Overcurrent of the Compressor
Complete the “Check This First” Flow Chart before
continuing.
Öòçèïö
AW24TL2HFA
AW30TL2HFA
AW36TL2HFA
31-5000936-1