Installation instructions
Installation in monolithic screed
Disperse the cement screed directly onto
the concrete slab and onto the underfloor
trunkings.
Installation in floating floor screed Installation in floating screed
Cement screed is applied onto an insulating
layer. The underfloor trunking is integrated in
this insulation layer.
The installation of trunking and universal
junction boxes is similar to the installation in
cement screed. In addition, the system must
be protected against the ingress of floating
screed during installation.
Installation in hot screed (UDS3 only)
When casting hot screed or mastic asphalt
temperatures of approx. 280 °C may occur.
This requires trunking and universal junction
boxes to be covered and insulated with bi-
tuminous corrugated board. Due to the high
temperatures, lines must not be installed
before the hot screed has completely cooled
down.
Position the universal junction boxes
according to the lay-out.
Notch universal junction boxes UDS3
Position the universal junction boxes on the
slab and secure them according to the lay-
out.
Create a notch in the corresponding sidewall
of the universal junction box to connect the
trunking. Use a wire cutter to cut out the
panel along the perforation as required.
Connect the trunking to
universal junction boxes UDS3
Connect the trunking to
universal junction box UDH
Bevel joints are possible
Insert the trunking through the notched side
part and move it up to the stop at the bottom
plate. The system must be protected by the
customer against the ingress of liquid screed
during installation.
Insert the trunking under the flexible screed
casing. Cut the flexible screed casing so that
the trunking is enclosed with the foil. The
system must be protected by the customer
against the ingress of liquid screed during
installation.
Universal junction boxes UDB3 and UDH3
allow trunking to be introduced at an angle
as specified. This layout makes the drawing
of cables more difficult. Up to 50° for junction
box UDH2 and UK190 or up to 40° for UDH2
and UK240.
Bekijk gratis de handleiding van Hager ESR1336029, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Hager |
| Model | ESR1336029 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 89748 MB |
Caratteristiche Prodotto
| Kleur van het product | Groen |
| Breedte | 45 mm |
| Diepte | 40 mm |
| Duurzaamheidscertificaten | RoHS |
| Aantal | 20 |