GYSFLASH 108.12 / 148.12 / 158.12 CNT FV
EN
27
• Case 2: Connecting to a load
When the Gysash detects the presence of a contact (e.g.: vehicle without a battery), it will automatically switch to EPS mode.
1
Auto - select
2.5
v
Supply
Contact detection (example: Vehicle without battery)
2
Supply
14.2 V
12 V
EPS
120
A
Launch the associated Supply mode (e.g.: EPS).
EPS
14.2
V
113
A
01:27:35 105.8
Ah
POWER UP MODE
2
1
Power - up
12
V
1- Mode
2- Nominal voltage
Starting the charge:
1 To start the mode, press the START/STOP button.
Power - up
14.0
V
113
A
00:00:25
5.8
Ah
2
1
3
4
5
1- Current mode
2- Voltage supplied by the charger
3- Current supplied by the charger
4- Time remaining
5- Amp-hours delivered
2
Your Gysash will apply a voltage to the lithium battery under
UVP protection to reactivate it.
If the battery is still not reactivated after a while, the charger stops and
indicates an error.
3
When this process is complete, your Gysash will automatically switch to
CHARGE mode (Lithium) to nish charging the battery.
Warning: reversing the polarity during use could damage the charger and
the electronics in the vehicle.
PROTECTIONS
This device is protected against short-circuits and reverse polarity. It features an anti-spark system, which prevents any sparks
when connecting to a battery. If there is no contact on the output, it does not deliver any current for safety reasons. This device is
protected against operator error via an internal fuse.
CONFIGURATION MENU