2 Conrm the restoration of the conguration.
Continue?
YES
3 The charger will then restore the penultimate conguration of the charger.
Loading
Export charging data on USB stick:
This function allows you to retrieve the charge history and data on a USB key, in order to be able to use them on a spreadsheet or
other.
1 Enter the "Export DATA" submenu
Export DATA
2 Conrm the recording of the charging data.
Continue?
Yes
3 The charger will then copy the charging data to the USB stick as les, « .CSV »
Loading
Custom conguration
List of modes and proles available for customization:
CHARGE MODE
Charge
type:
Charge
proles
Charging voltage
Pb-CHARGE
normal
2.40 V/cell Charging prole for lead batteries of the types Gel, MF, EFB, SLA...
AGM
2.45 V/cell
Charging prole for most AGM lead-acid batteries including START and STOP.
However, some AGM batteries require a lower voltage charge (Normal prole). Check the
battery manual if in doubt.
water
2.45 V/cell Charging prole for open liquid-type lead-acid batteries with plug.
Easy
2.40 V/cell
Charging prole dedicated to lead batteries that automatically adapts the charging current
according to the size of the battery.
However, for maximum charge optimization, it is recommended, when possible, to use
normal, AGM or liquid charge curves.
boost
2.42 V/cell
Maximum current charge for lead-acid battery. This type of charge is ultra-fast.
Warning : this type of charge must remain occasional in order to preserve bat-
tery life.
recovery+
2.40 - 2.50 V/cell
Charging prole for the recovery of severely damaged lead batteries. It is essential to
recover the battery outside the vehicle to avoid damaging the vehicle electronics and in a
well ventilated area.
Caution: Recovery voltage up to 4.0 V/cell.
Ca/Ca recov
2.45 - 2.66
V/cell
Charging prole for calcium battery recovery. The battery must be recovered outside the
vehicle to avoid damaging the vehicle’s electronics and in a well-ventilated area.
Caution: Recovery voltage can reach up to 2.75 V/cell.
Li-CHARGE
LFP/LiFePO4
3.60 V/cell Charging prole for Lithium batteries type LFP (Lithium Ferro Phosphate)
Li-ion std
4.20 V/cell
Charging prole for standard lithium-ion batteries based on Manganese or Cobalt (NMC,
LCO, LMO, MCO...)
LFP cell+
3.60 V/cell
Charging prole dedicated to LFP (Lithium Ferro Phosphate) type lithium-ion cells with
selection of the number of cells in series to be charged.
Li-ion cell+
4.20 V/cell
Charging prole dedicated to standard lithium-ion cells based on Manganese or Cobalt
(NMC, LCO, LMO, MCO...) with selection of the number of cells in series to be charged.
TRACTION
water
2.42 V/cell Charging prole dedicated to open lead traction batteries for forklift trucks.
gel
2.35 V/cell Charging prole dedicated to gel-type traction batteries for forklift trucks.
POWER MODES
Showroom
Maintains the battery's state of charge and supplies power when using the electrical consumers of a demonstra-
tion vehicle.
DIAG+
Supplies energy requirements during the vehicle diagnostic work.