GW Instek GPP-1323 handleiding
Handleiding
Je bekijkt pagina 73 van 157

OPERATION
73
16. Scroll knob key to move to the OVP Level
field followed by clicking knob key to enter
the field. Scroll knob key to adjust value
along with arrow keys to change among
digits followed by clicking knob key to
confirm OVP setting.
OVP
Level
5 % to 110 % rated voltage
17. Scroll knob key to move to the OCP Level
field followed by clicking knob key to enter
the field. Scroll knob key to adjust value
along with arrow keys to change among
digits followed by clicking knob key to
confirm OCP setting.
OCP
Level
5 % to 110 % rated current
18. Scroll knob key to move to the Bleeder
field followed by clicking knob key to enter
the field. Scroll knob key to turn on/off
bleeder followed by clicking knob key to
confirm bleeder action.
Bleeder
ON,OFF
.
Bekijk gratis de handleiding van GW Instek GPP-1323, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | GW Instek |
| Model | GPP-1323 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 14224 MB |







