GW Instek GPP-1323 handleiding

157 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 57 van 157
OPERATION
57
2. Scroll the knob key to move to the
Save/Recall field followed by clicking the
knob key to enter the Save/Recall page.
3. Scroll knob key to move to the Recall Mem
Set field. Click knob key to enter the field
followed by scrolling knob key to select one
of the options to recall setting. Click knob key
again to confirm.
Options
M1 to M5
Remote Sense
Remote sense is used to compensate for the voltage drop seen across
load cables due to the resistance inherent in the load cables. The
remote sense terminals are connected to the load terminals to
determine the voltage drop across the load cables.
Remote sense can compensate up to 1 volt for GPP-1000. Load cables
should be chosen with a voltage drop less than the compensation
voltage.
Warning
Ensure the output is off before handling the
remote sense connector.
Use sense cables with a voltage rating exceeding
the isolation voltage of the power supply.
Never connect sensing cables when the output is

Bekijk gratis de handleiding van GW Instek GPP-1323, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkGW Instek
ModelGPP-1323
CategorieNiet gecategoriseerd
TaalNederlands
Grootte14224 MB