GVision VW49CD-OD-40003 handleiding

51 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 42 van 51
WWW.GVISION-USA.COM
GVISION USA, INC. 30398 Esperanza, Rancho Santa Margarita, CA 92688 / Phone. 949-586-3338 / Fax. 949-272-4594 / Email. info@gvision-usa.com
42
Read Parameters from AD BOARD
Example ) Check Current Source - Set ID 01 (DP)
PC -> Monitor
Ethernet CMD(4Bytes) Serial CMD(6Bytes)
0x44 0x43 0x4F 0x4D 0x89 0x01 0xFE 0x01 0xF4
Monitor -> PC
(Response)
0x44 0x43 0x4F 0x4D
Ethernet CMD(4Byte)
0xF1
Serial CMD(1Byte)
0x01
PC->Monitor
Ethernet CMD(4Bytes)
Serial CMD(5Bytes)
Monitor -> PC
(Response)
Ethernet CMD(4Byte)
D C O M 0x89 ID(0~0xFE
)
0xFE PARM 0xF4
D C O M 0xF1 VALUE
Serial CMD(4Byte)
5) Control Command Packet
Virtual RCU (Remote Control Unit) : Emulates the Infra Red Remote Control
CMD Data1 Data2 Data3
Description
Data4
Command Target ID CMD Key Code
0xF4
(Start
Sending)
0x88
0xXX
(0x00~0
xFE)
0xFD
(RCU)
KEY_POWER 0x11
KEY_INPUT 0x13
KEY_MENU 0x43
KEY_EXIT 0x50
KEY_UP 0x47
KEY_DOWN 0x4B
KEY_LEFT(VOL -) 0x57
KEY_RIGHT(VOL +) 0x53
KEY_ENTER 0x04
KEY_MUTE 0x03
KEY_STILL 0x0A
KEY_INFO 0x06
KEY_SLEEP 0x0B
SET ID 0x51
SET ID EXIT 0x55