9.3 Error code
1. Indoor EEPROM on PCB failure—EE 9. Outdoor unit and IPOU communications
failure—F8
2. PG motor failure—F0 10. Compressor failure —E4/E3
3. Indoor pipe coil temperature sensor
failure—F3
11. IPM module malfunction—F9
4. Indoor temperature sensor failure—F1 12. Exhausting temperature sensor failure—F5
5. PG motor Zero crossing detection
anomaly-E1
13. Induction temperature sensor failure—E5
6. Outdoor system anomaly-E8 14. Outdoor pipe coil temperature sensor
failure—F4
7. Outdoor EEPROM on PCB failure—EF 15. Outdoor temperature sensor failure—F2
8. Indoor communications can not be
accepted—F6
16. Outdoor DC motor failure—E2