4
3
Ÿ Before connecting cables, ensure that the DC switches of the
WIT Inverter are OFF, and turn off the switch and breaker on the
AC side and the battery side. Otherwise, high voltages may
cause severe injuries.
Ÿ It must be operated by qualified and trained electrical
technicians. Technicians should observe instructions in this
manual and local regulations.
Ÿ High voltages may cause electric shocks and serious injury.
Please do not touch the WIT Inverter in operation.
Ÿ Do not install the inverter in potentially explosive and
flammable atmospheres.
Ÿ Each WIT Inverter must be equipped with an AC circuit breaker.
Multiple WIT Inverters cannot connect to the same AC circuit
breaker.
Ÿ Do not connect the load between the WIT Inverter and the
circuit breaker.
Ÿ If the cable is thick, do not shake the cable terminals after
tightening them. Otherwise, the loose connection may cause
overheating and device damage. Ensure that the terminals are
properly connected before starting the WIT Inverter.
Ÿ Ensure the correct polarity of the terminals before connecting
the PV array to the WIT Inverter.
Electrical Connections:
DANGER
Ÿ After turning off the DC switches and the AC breakers, wait for
at least five minutes before performing any operations to avoid
risks.
Ÿ Beware of high voltages which may cause electric shocks.
Ÿ It must be operated by qualified and trained electrical
technicians. Technicians should observe instructions in this
manual and local regulations.
Ÿ When the OLED screen indicates “PV Isolation low”, do not
touch the chassis as a ground fault may have been detected.
Ÿ To ensure good dissipation, clean the fan regularly.
Ÿ Do not use the air pump to clean the fan. Otherwise, the fan
may be damaged.
Maintenance and replacement:
WARNING
DANGER
WARNING
2.2 Symbol Conventions
Ÿ Upon receiving the product, check if the contents are intact and
complete. If any damage is found or any component is missing,
please contact your distributor.
Ÿ The maximum PV input voltage cannot exceed 1100V. The
battery input voltage cannot exceed 1000V.
Ÿ For the WIT Inverter that will not be put into operation in the
future, you should properly dispose of them by yourself.
Others:
WARNING
DANGER
WARNING
Symbol
Description
DANGER indicates a hazard with a high level of risk which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if
not avoided, could result in death or serious injury.
CAUTION indicates a hazard with potential risk which, if not
avoided, could result in minor or moderate injury.
NOTICE indicates that under certain circumstances, improper
operations could result in property damage.
Remind operators to check the instructions before installing or
operating the WIT Inverter.
CAUTION
NOTICE