dry contact function by setting "D-Time". When you set D-Export Power to enable the
dry contact function, the dry contact function may not work properly.
2. In the shinemaster parallel system, using the "Heater" option, you can only start the
1. The D-Bat setting item in the generator option will display different parameters
according to the type of battery connected. Min.SOC will displayed when a lithium
battery is connected, and Min.Vbat when a lead-acid battery is connected.
Note:
Chart 6.31
10. In the "Default" menu, you can press Enter to access the setting menu:
"Default set" means that all predefined parameters will be restored to the default value.
Please be cautious not to accidentally choose factory reset.
6.5.5 Three-phase total export limitation configuration
6.5.5.1 Setting procedure
Figure 6.32
Default Set
WorkMode WorkMode
YES
Press enter key to
make sure
Press enter key more
than 3 seconds to make sure
WorkMode
AutoloopDisplary
WorkMode
ExportLimit
ExportLimit
:ON/OFF
SingleExport
:ON/OFF
PowerRate:00%
Failsafe
:ON/OFF
LoadFstCtrl:SiEn
LoadFstCtrl:ThEn
6.5.5.2 Setting guide
(7) Press enteronce to enter the editing mode.
(1) Long press enterto access the "WorkMode" configuration page from the home
page for operating mode settings.
(2) Press downor press "up" to access the "ExportLimit" page for export limitation
settings.
(3) The first setting item is "ExportLimit", press enteronce to enter the editing mode.
(4) Press upor downto change the selected option, and set it to "ON".
(5) Press "enter" once to confirm your setting and exit the editing mode.
(6) Press downonce, and go to the next item to set "SingleExport" to ON to enable
independent export limitation for each phase.
(8) Press "up" or "down" key to change the selected option and set it to "OFF".
(11) Press enteronce to enter the editing mode.
(12) Press "up" or "down" key to set it to the desired value.
If the following configuration is not applicable, it goes directly to operation (18).
(9) Press "enter" once to confirm your setting and exit the editing mode.
(14) Press downonce to go to the next item to access the "Failsafe" for export
limitation failsafe settings.
(15) Press enteronce to enter the editing mode.
(16) Press "up" or "down" key to set it to the desired value.
(13) Press "enter" once to confirm your setting and exit the editing mode.
(17) Press "enter" once to confirm your setting and exit the editing mode.
(18) Press downonce to go to the next item "LoadFstCtrl" (Load First Control).
(19) Press enteronce to enter the editing mode.
(21) Press "enter" once to confirm your setting and exit the editing mode.
(22) Finally, press "Esc" to exit settings.
(10) Press downonce to go to the next item to set the "PowerRate" limited feed-in
power in percentage.
(20) Press "up" or "down" key to change the setting to "ThEn"(Three-phase Enable).
6.5.6 Three-phase independent export limitation configuration
6.5.6.1 Setting procedure
Figure 6.33
WorkMode
AutoloopDisplary
WorkMode
ExportLimit
ExportLimit
:ON/OFF
SingleExport
:ON/OFF
PowerRate:00%
Failsafe
:ON/OFF
LoadFstCtrl:SiEn
LoadFstCtrl:ThEn
6261