Note:
It is suggested that the distance between the battery and the SPH be no longer than 5 m,
and the power cable specification be greater than 10 AWG.
Figure 5.30
5.4.5 Connecting the meter terminal
Step 7: Insert the RJ45 plug of the network cable into the “METER”connector on the
inverter until it snaps into place.
Step 5: Route the LAN cable through an opening in the cable support sleeve.
Step 4: Remove the filler plug from the cable support sleeve.
Step 2: Thread the swivel nut over the LAN cable.
To monitor the energy flow using the meter, please proceed as follows to connect the
meter:
2. For details about wiring the meter, please refer to the User Manual of the meter.
Step 6: Thread the LAN cable through the cable gland.
Step 8: If no other cables need to be installed, lock the waterproof cover to the inverter
with screws.
Step 1: Connect the LAN cable with the RJ45 connector, referring to Section 5.2.
Note:
Step9: Screw the swivel nut onto the waterproof cover.
Step 3: Press the cable support sleeve out of the cable gland.
1. The meter must be purchased from Growatt. Meters of other brands would fail to
communicate with the SPH inverter.
To Battery Power
Figure 5.31
Note:
The LAN cable connecting the meter is 15 m in length with the RJ45 connector at both
ends (one end connected to the meter and the other connected to the inverter). If the
cable is not long enough, you can extend the cable to a length of up to 25 m. Please refer
to the figure below:
Figure 5.32
METER
Figure 5.33
Figure 5.34