Growatt SPF3000-6000T-HVM-G2 handleiding

48 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 45 van 48
43
Warning code 15
The input status is different in
parallel system.
Check if AC input wires of all
inverters are connected well.
Warning code 16
Input phase is not correct.
Change the input phase S and
T wiring.
Warning code 17
The output phase not correct
in parallel.
1. Make sure the parallel
setting are the same
system(single or parallel;
3P1,3P2,3P3).
2. Make sure all phases
inverters are power on.
Warning code 19
No battery alarm
Check that the battery is
connected to the machine
Buzzer beeps
continuously and red
LED is on. (Fault
code)
Fault code 20
BMS communication failed
1. Check the BMS
communication wire to see if
it’s well connected
2. Check the transceiver signal
Fault code 51
Over current or surge
Restart the unit, if the error
happens again, please return
to repair center.
Fault code 56
MOS overcurrent
Restart the unit, if the error
happens again, please return
to repair center.
Fault code 60
Negative power fault
1. Check whether the AC
output connected to the
grid input.
2. Check whether Program 8
settings are the same for all
parallel inverters
3. Check whether all neutral
wires of all parallel units are
connected together.
5.If problem still exists,
contact repair center.
Fault code 80
CAN fault
1. Check whether the parallel
communication cables are
connected well.
2. Check whether Program 23
settings are right for the
parallel system.
3. If problem still exists,
contact repair center
Fault code 81
Host loss
Note: To restart the inverter, all power sources need to be disconnected. After the LCD screen light is off, only
use the battery to boot.

Bekijk gratis de handleiding van Growatt SPF3000-6000T-HVM-G2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkGrowatt
ModelSPF3000-6000T-HVM-G2
CategorieNiet gecategoriseerd
TaalNederlands
Grootte9112 MB