6.8 Active power control with smart meter , ripple control
signal receiver
This series inverter has integrated generation limitation control and export limitation
Functionality.The generation control function is used to control the active or apparent
power output levels of an inverter.The export limit control function for an inverter is used
to control the generation from an inverter to manage the export power level from an
electrical installation to the grid. To use this function, you can connect smart meter.The
smart meter model is Eastron SDM120CT-M(40mA).The primary aperture is
10mm,output cable length is 5m.The arrow on the CT must pointing towards the
inverter.The detailed information about the Meter,please refer to Annex -Eastron
SDM120CT-M(40mA) user manual.
The position of export limitation Meter must between the Inverter &
Load and gird.
Multiple inverter combination is not suitable in Australia.
The smart meter can be used only up to 2000m altitude.
Information
27
28
Active power control with a Radio Ripple Control Receiver(RRCR).
Step 3 Push the threaded sleeve to connection terminal until both are locked tightly on
the inverter.
Uninstall signal connector
Step 1 Press the fasteners and pull it out from the inverter.
Step 2 Insert the H type tool and pull it out from the socket.
6.7 Grounding the inverter
The inverter must be connected to the AC grounding conductor of the power
distribution grid via the ground terminal (PE) .
WARNING
Because of the transformerless design, the DC positive pole and DC
negative pole of PV arrays are not permitted to be grounded.
The inverter side
The inverter side
RS485
LOAD
Manufacturer
Eastron
Type
SDM120CT-M(40mA)