Growatt MID 30-50KTL3-X2 handleiding
Handleiding
Je bekijkt pagina 25 van 28

16 EU Declaration of conformity
With the scope of EU directives:
• 2014/35/EU Low Voltage Directive (LVD)
• 2014/30/EU Electromagnetic Compatibility Directive (EMC)
• 2011/65/EU RoHS Directive and its amendment (EU)2015/863
Shenzhen Growatt New Energy Co. Ltd confirms that the Growatt inverters and
accessories described in this document are in compliance with the above mentioned
EU directives. The entire EU Declaration of Conformity can be found at www.ginverter.com.
17.1 Parameter
Specification 17
43
44
MID
15KTL3-XL2
MID
17KTL3-XL2
MID
20KTL3-XL2
MID
22KTL3-XL2
MID
25KTL3-XL2
Input data(DC)
Max. recommended
PV power(for
module STC)
22.5kW
25.5kW
30kW
33kW
37.5kW
Max. DC voltage
1100V
Start voltage
200V
Nominal voltage
360V
MPP voltage range
200-850V
No. of MPP trackers
4
No. of PV strings per
MPP trackers
2/2/2/2
Max. input current
per MPP trackers
32A*4
Max. short-circuit
current per MPP
trackers
40A*4
Backfeed current to
PV array
0A
Output data(AC)
AC nominal power
15kW
17kW
20kW
22kW
25kW
Max. AC apparent
16.6kVA
18.8kVA
22.2kVA
24.4kVA
27.7kVA
Nominal AC
voltage/range
127V/220V
133V/230V
AC grid
frequency/range
50/60 Hz
45~55Hz/55-65 Hz
Max. output current
43.7A
49.6A
58.3A
64.2A
72.9A
AC inrush current
60A
Max. output fault
current
148.8A
Max. output
overcurrent
Protection
148.8A
Power
factor(@nominal
power)
>0.99
Adjustable power
factor
0.8Leading ...0.8Lagging
THDi
<3%
Model
Specifications
Bekijk gratis de handleiding van Growatt MID 30-50KTL3-X2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Growatt |
| Model | MID 30-50KTL3-X2 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 4972 MB |