Growatt MID 30-40KTL3-X-AU handleiding
Handleiding
Je bekijkt pagina 24 van 35

42
41
Troubleshooting 14
14.1 Error message
14.2 System error
When a malfunction occurs, an error message will be displayed on the OLED screen.
Faults include system faults and inverter faults.
In some cases, you may be advised to contact Growatt, please provide the following
information.
Information about the inverter:
●Serial number
●Model
●Error message on OLED
●A short description of the problem
●Grid voltage
●DC input voltage
●Can you reproduce the failure? If so, how?
●Has this problem occurred in the past?
●What were the environmental conditions when the problem occurred?
Information about photovoltaic panels:
●PV panel manufacturer's name and model
●Panel output power
●Voc of the panel
●Vmp of the panel
●Imp of the panel
●The number of panels in each string
●If you need to replace the device, please ship it to the original box.
Warning Code
Warning
message
Description
Suggest
Warning 200
Panel access failure
1.Check whether the panel is normal after shutting
down;
2.If the fault message still exists,contact the
manufacturer.
Warning 201
String/PID quick
connect terminal
abnormal
1.Check the string terminal wiring after shutdown;
2.If the fault message still exists, contact the
manufacturer.
Warning 202
DC lightning protection
device alarm
1.Check the DC lightning arrester after shutdown;
2.If the fault message still exists,contact the
manufacturer.
Warning 203
Panel short circuit
1.Check whether the first or second road panel or
circuit is short-circuited;
2.If the fault message still exists, contact the
manufacturer.
Warning 204
Dryconnect function
abnormal
1.Check the dry node wiring after shutdown;
2.If the fault message still exists,contact the
manufacturer.
Warning 205
Boost drive abnormal
1.Restart the inverter;
2.If the fault message still exists,contact the
manufacturer.
Warning 206
AC SPD functIon
abnormal
1.After shutdown,Check the AC SPD.
2.If error message still exists,contact manufacturer.
13 Maintenance , Repair and Cleaning
(Australia model only)
Prior to removal of any cover for maintenance or repair, turn off the
switch on the AC and DC sides.
WARNING
Bekijk gratis de handleiding van Growatt MID 30-40KTL3-X-AU, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Growatt |
| Model | MID 30-40KTL3-X-AU |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 6081 MB |