Ÿ The device damage caused by failure to seal the output terminal gaps as
instructed is beyond the scope of warranty and Growatt New Energy shall
not be liable for the damage.
2>Open the AC junction box first, and then pass the cable through the waterproof
silicone gasket .Determine the stripping length (approximately 30mm) according to the
specifications of the crimping terminal. Use crimping tools to crimp the wires and
terminals, then connect the cables to the corresponding channels through the
waterproof interface, and tighten the screws.
Fig 6.2
Fig 6.3
3> Upon completion of the AC wiring, remember to seal the water-proof silicone mat
with the fireproof mud in order to ensure good waterproof performance.
Fig 6.4
6.2 Connection On DC Side
• Before electrical connection please ensure the inverter DC switch is at
"OFF” also disconnect AC switch, otherwise the high voltage from inverter
may cause life risk.
• Only trained authorized electrical technician can do the electric
connection also please follow the connection procedures in this manual
along with local country's regulations.
• High voltage may cause electric shocks and serious injury please do not
touch the inverter.
• Do not place flammable or explosive materials around the inverter.
• Please ensure that the following conditions are met, as failure to do so
may damage the inverter or pose a fire hazard. In such cases, the company
shall not be liable for any consequences.
Notice: The sunlight will generate voltage on the solar panels, after serial connection,
the high voltage may injure personnel, so before connect DC input cable you need cover
solar panels with light-tight materials and make sure the inverter DC switch is at
"OFF”status, otherwise high voltage may injure personnel.
19 20
WARNING
Diagram of how to install a terminal:
DANGER
WARNING
Fireproof mud
1>Each string's maximum open circuit voltage cannot exceed 1500Vdc,other- wise it
could lead to fire or damage the inverter. If the inverter was damaged by higher
maximum open circuit voltage (higher than 1500Vdc),product warranty will be forfeited
and Growatt will not take any responsibility.
2>Each string solar panels should be same brand and same model.The inverter shall be
used with IEC 61730 Class A rating PV module.
3>Under any circumstance, the maximum short circuit current should not exceed 50A.
4>The total panels power should not exceed 1.5 times of inverter input power.
5>To optimize system settings, recommend two strings with same amount solar panels.
6>Please use the positive and negative metal contacts and the DC connectors delivered
with the inverter package. Using other incompatible models may result in severe
consequences, which will void the warranty.
7>When assembling the DC connectors, pay attention to the correct polarity and label
the positive and negative cables.
8>Crimp the PV metal contact with a dedicated crimper. Using an inappropriate
crimping tool may lead to severe consequences, and any device damage caused by this is
not covered by the warranty.
9>Cables with high rigidity are not recommended for the DC input as bending of cables
may lead to poor contact of terminals.
10>According to the specification of the crimping terminal, determine the stripping
length, crimp the wire and terminal with the crimping pliers, and connect them to the
corresponding connector housings separately, and hear the click sound to ensure the
connection is good.After snapping the positive and negative connectors into place, pull
the cables slightly to ensure that they are securely in place.
11>Connectors need to be fit with male and female terminals, before connecting
panels with inverter please make sure the positive pole and negative pole, namely the
solar panels'positve pole connect to”+” negative pole connect to”-”.