26
External CAN
Communication
failure
Communication loss
between inverter and
battery
1. 1. There is no safety threat
and user should stop using
battery.
2. Check if inverter and battery
communication terminal is
well connected.
3. If inverter and PACK cannot
communicate when the
communication wire is
confirmed well connected,
user should contact installer
to repair battery.
Interior CAN
Communication
failure
Communication loss
between two parallel
1. Check CAN connection
between two batteries, CAN
connection between Link-in and
Link-out;
Parallel
connection
failure protection
Communication failure
between two parallel
connected battery
1. Check CAN connection
between two batteries, CAN
connection between Battery and
Inverter;
(ALM Light on)
Discharge short
circuit
External short circuit of
battery
There is safety risk and user
should stop using battery, User
should contact installer to repair
inverter and battery
Pre-charger short
circuit
Pre-charger
overtime circuit
Parallel failure
The pack type is
different
There is safety risk and user
should stop using battery, User
should contact installer to use
the same battery in Parallel.
Main circuit fault
BMS main power
circuit failure
There is safety risk and user
should stop using battery. User
should contact installer to repair
battery
MOS control
failure
Turn off MOS
tube,there is still
current
There is safety risk and user
should stop using battery. User
should contact installer to repair
battery