5 Power on and off the Battery
The installation and use of batteries involve much specialized knowledge. Therefore, technicians
should be given appropriate technical training and obtain operational certificates in compliance
with local laws and regulations. Please ensure technicians have obtained training certificate
before operation.
Please stand on dry insulating objects and do not wear conductive material such as watches and
necklace during operation. Insulated tools should be used
Do not contact any positions with potential difference
Prohibition sign should be hung on the battery: " Non - professionals, do not touch"
If any abnormalities occur during the startup phase, power off the PACK immediately. After
problem confirmed, proceed again.
Make sure the inverter is turned off before checking the PACK.
5.1 Power On
When multiple batteries are connected in parallel or multiple clusters of batteries are connected in
parallel, press one of the battery power buttons and all the batteries connected in parallel can be
turned on.
Power on the PACK by pressing power button(t>1S)
Serial
Procedures
Acceptation criteria
1
Connect the battery
and inverter
Make sure the wiring harnesses are well
connected
2
Close the breaker of the
BATTERY
Make sure the breaker is ON
3
Press POWER button for
one second. Observe the
LED indication on panel.
1. If both RUN/ALM and SOC lights turn on
normally, PACK is powered on successfully.
If ALM light turns red, there is a failure and
should solve it before power on again.
Power on the PACK by Inverter
1
Connect the battery and
inverter
Make sure the wiring harnesses are well
connected
2
Close the breaker of the
BATTERY
Make sure the breaker is ON
3
Power on the inverter to
charge the battery
1. If both RUN/ALM and SOC lights turn
on normal, BATETRY powers on successfully.
2. If ALM light turns red, there is a
failure and should solve it before power on
again.
5.2 Power off
Press the power switch for 3 seconds and release it, battery off, all LED lights off. If multiple
batteries are connected in parallel, only press the power switch of any one of the batteries for 3
seconds and then release it, the other batteries can be turned off