4We recommend installing a circuit breaker between the inverter and the battery. For the
specifications of the circuit breaker, we recommend using a molded case circuit breaker with a
rated operating voltage greater than 80Vdc and a rated operating current greater than 200A.
4.4.5 Battery pack power expansion installation
*
Make sure all batteries are in off mode and the battery circuit breaker is off
* Make sure there are no tangled cables after the battery wiring
* Supports parallel connection of up to 12 battery packs to form a 66kW expansion storage system
Operation Step 1: Connect the network cable
1. Insert one end of the network cable A into the inverter interface of battery 1 and the other end
into the BMS network port of the inverter
2. Connect the LINK-OUT connector of battery 1 and the LINK-IN connector of battery 2 using
network cable B. Connect the rest of the batteries in the same way until the last battery is
connected.
Operation Step 2: Connect the ground wire
Connect the ground terminal of each battery to the grounding strip.
Operation Step 3: Connect the power cord.
Connect the +/- terminal of each battery into the +/- terminal of the latter battery separately, and
then connect the wires to the inverter.
Operation Step 4: Insert the shorting cap.
Insert the DODI port of the battery pack other than pack 1 into the shorting cap