Gree GSC24UZ handleiding

33 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 28 van 33
23
burrs from getting into the pipe.
the length is equal
pipe and outdoor valve;
install the union nut on
the pipe.
union pipe
pipe
Remove the burrs with shaper and prevent the
C: Put on suitable insulating pipe
Working temperature range
smooth surface
improper expanding
uneven
thickness
leaning
damaged
crack
surface
Remove the union nut on the indoor connection
Expand the port with expander.
expander
pipe
hard
mold
A(mm)
Max Min
Φ6 - 6.35(1/4")
1.3 0.7
Φ9 - 9.52(3/8") 1.6 1.0
Φ12-12.7(1/2")
1.8 1.0
Φ15.8-16(5/8")
2.4 2.2
Outer diameter
(mm)
B: Remove the burrs
D: Put on the union nut
E: Expand the port
F: Inspection
shaper
downwards
pipe
Check the quality of expanding port. If there is
NOTICE
43/26
Indoor side
DB/WB(°C)
Outdoor side
DB/WB(°C)
32/23
cooling
Maximum
NOTE
"A" is different according to the diameter, please refer
to the sheet below:
The operating temperature range (outdoor temper-
ature) for cooling only unit is 18°C~43°C.
any blemish, expand the port again according to
the steps above.