Gossen Metrawatt PROFITEST EMOBILITY handleiding
Handleiding
Je bekijkt pagina 4 van 22

4 | 22
Application
Measurement Cables and Establishing Contact
• Plugging in the measurement cables
must not necessitate any undue force.
• Never touch conductive ends (e.g. of
test probes).
• Do not touch the insulation measuring
instrument’s test probes during insula-
tion resistance measurements!
• Fully unroll all measurement cables
before starting a test/measurement.
Never perform a test/measurement with
the measurement cable rolled up.
• When using a test probe with coil cord:
Grip the tip of the test probe firmly, for
example if it has been inserted into a jack
socket. Tensioning at the coil cord may
otherwise cause the test probe to snap
back resulting in possible injury.
Fuses
• The instrument may only be used as long
as the fuses are in flawless condition.
Defective fuses must be replaced.
• Never bridge the fuses. Never put the
fuses out of operation.
2 Application
2.1 Intended Use /
Use for Intended Purpose
The PROFITEST EMOBILITY is an adapter
for standards-compliant testing of single and
3-phase, mode 2 and 3 charging cables with
simulation of faults in accordance with DIN
EN 50678 VDE 0701 / DIN EN 50699 VDE
0702 and per manufacturer’s specifications.
Some measurements/tests can be per-
formed with the adapter only, others require
a compatible test instrument or accessory.
Test Adapter
The following faults can be simulated using
the test adapter with mains supply to a
charging cable:
• Interruption of individual conductors
(undervoltage detection)
• Reversed wires
•PE to phase
(Interference voltage in the protective
conductor due to connection of the
phase conductor to the protective con-
ductor)
Evaluation of the charging cable’s reaction to
each fault is strictly visual in this case via the
ICCB indicator lamp or the LEDs at the test
adapter.
Test Adapter + Test Instrument
The following additional measurements/tests
are possible when a compatible test instru-
ment (see below) is connected:
• Protective conductor resistance mea-
surement of the charging cable
• Insulation resistance measurement of the
charging cable
• RCD tripping test at the ICCB with nomi-
nal residual current
(not possible with SECUTEST ST PRO.)
• Measurement of time to trip of the RCD
at the ICCB
• Guided test sequences (device-specific)
(not possible with PROFITEST MXTRA
and PROFITEST MTECH+)