22
NOZZLE TABLE
Gas type, pressure
Auxiliary burner
Normal burner
Wobbe number
Standard
max
min
max
min
Natural gas H
Wo=45,7÷54,7 MJ/m
3
Natural gas E,
Natural gas E+
Wo=40,9÷54,7 MJ/m
3
G20, p=20 mbar
Nominal heat load (kW)
1,0
0,48
1,9
0,48
Consumption (l/h)
95
46
181
46
Nozzle type (1/100 mm)
72 X
26
1)
/ 35
2)
103 Z
26
1)
/ 35
2)
Nozzle ID
690771
568169
Liquefied gas 3B/P
Wo=72,9÷87,3 MJ/m
3
G30, p=30 mbar
Nominal heat load (kW)
1,0
0,48
1,9
0,48
Consumption (g/h)
73
35
138
35
Nozzle type (1/100 mm)
50
26
1)
/ 35
2)
68
26
1)
/ 35
2)
Nozzle ID
690780
568175
Gas type, pressure
Large burner
Wobbe number
max
min
Natural gas H
Wo=45,7÷54,7 MJ/m
3
Natural gas E,
Natural gas E+
Wo=40,9÷54,7 MJ/m
3
G20, p=20 mbar
Nominal heat load (kW)
3,0
0,76
Consumption (l/h)
286
72
Nozzle type (1/100 mm)
130 H3
33
1)
/ 46
2)
Nozzle ID
574285
Liquefied gas 3B/P
Wo=72,9÷87,3 MJ/m
3
G30, p=30 mbar
Nominal heat load (kW)
3,0
0,76
Consumption (g/h)
218
55
Nozzle type (1/100 mm)
86
33
1)
/ 46
2)
Nozzle ID
574287
Gas type, pressure
Oven burner
(thermostat)
Oven burner
(tap)
Infra
burner
Wobbe number
max
min
max
min
Natural gas H
Wo=45,7÷54,7 MJ/m
3
Natural gas E,
Natural gas E+
Wo=40,9÷54,7 MJ/m
3
G20, p=20 mbar
Nominal heat load
(kW)
3,0
0,8
3,0
0,8
2,2
Consumption (l/h)
286
76
286
76
210
Nozzle type
(1/100 mm)
117 Y
33
1)
/ 46
2)
117 Y
33
1)
/ 46
2)
108 Y
Nozzle ID
568171
568171
568173
Liquefied gas 3+, B/P
Wo=72,9÷87,3 MJ/m
3
G30, p=30 mbar
Nominal heat load
(kW)
3,0
0,8
3,0
0,8
2,2
Consumption (g/h)
218
58
218
58
160
Nozzle type
(1/100 mm)
82
33 / 46
2)
82
33 / 46
2)
75 H3
Nozzle ID
568177
568177
568178
1)
Copreci /
2)
Sabaf
Regulation screws for liquefied gas are installed and set in factory to the gas type for which the factory default
settings apply.
When modifying the appliance for use with a different type of gas, the regulation screw has to be tightened or undone
to set the required gas flow (do not undo the regulation screw by more than 1.5 turns).
Burner power is indicated by observing the upper Hs caloric value.
Connection to gas supply and adjustment to a different type of gas may only be carried out by an expert
authorized by the gas distributor or an authorized service technician!