NOZZLE TABLE
The
diameters in hundredths of millimetre are stamped on the nozzle.
Burner kW rated load
Ø Nozzle bore in mm
G20
20 mbar
G30
50 mbar
G30
29 mbar
Oven burner
3,40
1,30
0,76
0,88
Grill burner
2,80
1,18
0,72
0,83
A
DJUSTMENTS OF THE MINIMUM SETTING FOLLOWING CONVERSION
TO A DIFFERENT GAS TYPE:
P
roceed to disassemble the front panel:
-
for the front panel, unscrew the two rear fixing screws
-
for glass fronts, unscrew the two lock rings under the knob.
Conversion from natural gas to liquid gas
After removing the front panel, insert the screwdriver in the hole in the front wall of the instrument
panel and turn regulation screw A clockwise.
Conversion from liquid gas to natural gas
After removing the front panel, light the over with thermostat set to 250°C for at least 10-15
minutes. Then, turn the thermostat to the minimum position. Then turn the bypass screw A
counterclockwise until you see a reduced by stable flame. Check that the flame does
not go out
when the door of the oven is opened and closed repeatedly. If the flame goes out, slight increase
the minimum regulation setting.
After converting the appliance to a different type of gas, remember to change the data plate to one
with the new data (gas type and pressure).
<