8
2.3.3 Battery Safety
DANGER
The battery system exists high voltage during the equipment running. Keep Power Off before
any operations to avoid danger. Strictly follow all safety precautions outlined in this manual and
safety labels on the equipment during the operation.
Do not disassemble, modify, or replace any part of the battery or the power control unit without
official authorization from the manufacturer. Otherwise, it will cause electrical shock or damages
to the equipment, which shall not be borne by the manufacturer.
Do not hit, pull, drag, squeeze or step on the equipment or put the battery into fire. Otherwise,
the battery may explode.
Do not place the battery in a high temperature environment. Make sure that there is no direct
sunlight and no heat source near the battery. When the ambient temperature exceeds 60 , it
will cause fire.
Do not use the battery or the power control unit if it is defective, broken, or damaged. Damaged
battery may leak electrolyte.
Do not move the battery system while it is working.
Contact after-sales service if the battery shall be replaced or added.
A short circuit in the battery may cause personal injury. The instantaneous high current caused
by a short circuit can release a large amount of energy and may cause a fire.
WARNING
If the battery discharged completely, please charge it in strict accordance with the
corresponding model's user manual.
Factors such as: temperature, humidity, weather conditions, etc. may limit the battery's current
and affect its load.
Contact after-sale service immediately if the battery is not able to be started. Otherwise, the
battery might be damaged permanently.
Emergency Measures
Battery Electrolyte Leakage
If the battery module leaks electrolyte, avoid contact with the leaking liquid or gas. The electrolyte is
corrosive. It will cause skin irritation or chemical burn to the operator. Anyone contact the leaked
substance accidentally has to do as following:
Breath in the leaked substance: Evacuate from the polluted area, and seek immediate medical
assistance.
Eye contact: Rinse your eyes for at least 15 minutes with clean water and seek immediate medical
assistance.
Skin contact: Thoroughly wash the touch area with soap and clean water, and seek immediate
medical assistance.
Ingestion: Induce vomiting, and seek immediate medical assistance.
Fire
The battery may explode when the ambient temperature exceeds 150. Poisonous and hazardous
gas may be released if the battery is on fire.
In the event of a fire, please make sure that the carbon dioxide extinguisher or Novec1230 or FM-
200 is nearby.
The fire cannot be put out by ABC dry powder extinguisher. Firefighters are required to wear full
protective clothing and self-contained breathing apparatus.