03 Product Introduction User Manual V1.2-2025-01-13
12
3.4.4 Nameplate
The nameplate is for reference only.
Goodwe trademark, product type, and
product model
Technical parameters
Safety symbols and certication marks
Contact information and serial
number
3.5 Functionalities
PID Recovery (Optional)
During the operation of PV panels, there is a potential dierence between the output electrodes
and the grounded frame of the panels. Over an extended period, this can lead to a decrease
in the power generation eciency of the panels, which is known as the Potential Induced
Degradation (PID) eect.
The PID function of this unit operates by elevating the voltage dierential between the PV
panels and their frames to a positive value (termed as positive-voltage elevation). This eectively
suppresses the PID eect and is applicable to P - type PV panels as well as N-type PV panels that
necessitate positive - voltage elevation for PID suppression. For N - type PV panels that demand
negative - voltage reduction to suppress the PID eect, it is advisable to deactivate this function.
Regarding whether an N - type module falls into the category that requires positive - voltage
elevation for PID suppression, please consult the module supplier.