GVC-390 0422
13
REFILLING THE WATER TANK DURING OPERATION
An indicator light will tell you when there is no more water in the cleaner (E-g.2) If this
happens the boiler stops heating automatically.
WHAT TO DO
Switch off the boiler heating switch.
Continue working to use up any remaining steam in the boiler. If this is not done, you
will not be able to open the self-locking ller cap.
Switch off the main switch.
Remove the plug from a socket.
With a towel to protect your hand carefully unscrew the self-locking cap and let any
remaining steam escape.
Remove the safety cap.
Fill the tank with water as described in section “Setting up/How to ll the
boiler” (page-9).
Re-connect the appliance and start up as described in section “How to start up”
(page-10).
MAINTENANCE
DESCALING (Fig. 14) (every
3-4 weeks)
ATTENTION: Never
descale the appliance
when still warm.
Unplug.
Fill the tank with tap
water. Do not add
anything other than
simple tap water.
Hold the appliance
upright and shake
thoroughly to loosen
any scale in the
boiler chamber.
Open the drain at the bottom of the boiler (14) using the key on the safety cap.
Collect the water coming from the boiler.
Rinse the repeatedly with tap water (ONLY TAP WATER) until there are no further
traces of scaling.
Close the drain at the bottom of the boiler (14).
CLEANING THE APPLIANCE
Clean the appliance and accessories with a damp cloth. Never use steam or immerse
in water.
Fig. 14