REFILLING THE WATER TANK DURING OPERATION
An indicator light will tell you when there is no more water in the cleaner (E-g.2) If this
happens the boiler stops heating automatically.
WHAT TO DO
• Switch off the boiler heating switch.
• Continue working to use up any remaining steam in the boiler. If this is not done, you
will not be able to open the self-locking ller cap.
• Switch off the main switch.
• Remove the plug from a socket.
• With a towel to protect your hand carefully unscrew the self-locking cap and let any
remaining steam escape.
• Remove the safety cap.
• Fill the tank with water as described in section “Setting up/How to ll the
boiler” (page-9).
• Re-connect the appliance and start up as described in section “How to start up”
(page-10).
MAINTENANCE
DESCALING (Fig. 14) (every
3-4 weeks)
ATTENTION: Never
descale the appliance
when still warm.
• Unplug.
• Fill the tank with tap
water. Do not add
anything other than
simple tap water.
• Hold the appliance
upright and shake
thoroughly to loosen
any scale in the
boiler chamber.
• Open the drain at the bottom of the boiler (14) using the key on the safety cap.
• Collect the water coming from the boiler.
• Rinse the repeatedly with tap water (ONLY TAP WATER) until there are no further
traces of scaling.
• Close the drain at the bottom of the boiler (14).
CLEANING THE APPLIANCE
Clean the appliance and accessories with a damp cloth. Never use steam or immerse
in water.
Fig. 14