X4 Atom PSU12 manual (v1.0) from software version: v1.21 8
4.2 DMX
USITT DMX-512 Standard input/output in XLR 5-pin connectors.
Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] / Pin 4 & 5 N.C.
The DMX- Addressing starts at the DMX- Address [001].
4.3 Output to X4 ATOM Head
12 x 4-pin XLR connectors for signal and power to Atom Head only.
Pin 1 = [Ground] / Pin 2 = [Data +] / Pin 3 = [Data -] / Pin 4 = [V+ 24V]
Do not exceed 60m / 200ft. cable length for any output to the X4 ATOM
head.
Attention: Do only connect one (1) GLP X4 ATOM head per output. Never
connect any other equipment to this output as this may damage the PSU
and/or the connected fixture(s).
5 The Menu Field
ß
DOWN - UP
à
ß
MODE - ENTER
à
Level1
Level 2
Level 3
Level 4
Remark
DMX Start
Address 001
Set the DMX start address
Special
Manual
DMX
Manual control of all fixture functions
Master
Intensity
Manual control for Master Intensity
You’ll find the control board on the front side of the X4 ATOM
PSU 12.
It allows you to make all necessary adjustments of the fixture.
With the Mode-key you get into the main menu. Afterwards you
can Navigate through the menu with the Up/Down-keys. Push
the Enter-key to get in the next menu level or to confirm your
settings. Make them and set functions ON/OFF with the
Up/Down-keys. Confirm and save it with the Enter-key (the
display shows OK). Push the Mode-key to cancel the entry and
go back to the main menu.